Cell and Gene Therapy Logistics: Keeping Doses Below –150 °C

Cell and gene therapy logistics is the controlled movement of living cells from the collection centre to manufacturing and back to the patient as a finished dose, without the product ever warming above –150 °C. It relies on qualified dry shippers, continuous temperature logging, an unbroken chain of identity and handovers that follow Good Distribution Practice (GDP).

In cell and gene therapy, logistics is not a back-office function. An autologous CAR-T dose is made from the cells of exactly one patient. If it is lost in transit, there is no replacement on a shelf, only a second apheresis and several more weeks of manufacturing, assuming the patient's condition still allows it. This article walks through the vein-to-vein chain, shows where temperature excursions actually happen, and sets out what containers, data loggers and documentation need to deliver.

The vein-to-vein chain: every step of a cell therapy supply chain

An autologous therapy passes through several stations. At each one, responsibility changes hands, and every handover is a potential break in the cold chain.

Apheresis at the collection centre: the patient's white blood cells are collected. Depending on the process, they ship fresh at 2–8 °C or are cryopreserved on site.

Shipping to manufacturing: cryopreserved starting material travels in the vapour phase of liquid nitrogen to the manufacturer, often across borders.

Manufacturing and release: cells are modified, expanded, filled into cryobags and frozen at a controlled rate. Until QP release, the dose sits in quarantine in a cryogenic tank.

Shipping to the treatment centre: the released dose travels in a dry shipper below –150 °C to the hospital.

Storage and thaw at the clinic: the hospital receives the dose into its own cryogenic storage and thaws it only immediately before infusion.

Allogeneic therapies made from donor cells skip the patient-specific return leg. Instead, larger batches are distributed to many sites, and on-site storage tends to last longer. For the storage side of CAR-T products, see our article on cryogenic storage for CAR-T cell therapies.

Why cell and gene therapy logistics must stay below –150 °C

The glass transition of water lies at roughly –135 °C. Below it, cryopreserved cells undergo no meaningful ice recrystallisation or metabolic activity. The –150 °C limit adds a safety margin to that threshold. Above it, ice crystals can grow and damage cell membranes. The damage is invisible from outside and only shows up after thaw as reduced viability.

For cryogenic shipping, that means the average temperature is not what matters. Every short spike does. A few minutes of exposure during a transfer can be enough to put a dose in question, which is why manufacturers and regulators expect continuous recording across the whole route and a documented assessment of every excursion.

Where temperature excursions really happen

Excursions rarely happen on the road or in the aircraft hold, provided the container was prepared properly. The risky moments are the ones where people intervene:

  • Loading and unloading: the dose moves from the storage tank into the dry shipper, or back. Without pre-cooled tools and a rehearsed sequence, bag temperature rises within seconds.
  • Poorly conditioned shippers: a dry shipper whose absorbent is not fully saturated with liquid nitrogen will not reach its rated hold time.
  • Customs and delays: border checks, strikes and weather extend transit. If hold time was calculated too tightly, there is no reserve left.
  • Container orientation: a dry shipper lying on its side loses hold time quickly. Orientation labels and tilt monitoring help to detect it.
  • Opening for inspection: every unnecessary opening, for example at a security check, costs cold.

To validate the full chain from freezing to storage to shipping, read our guide to cryogenic cold chain validation.

Dry shippers: the workhorse of cryogenic shipping

A dry shipper is a vacuum-insulated transport container whose inner chamber is lined with a porous absorbent. Before dispatch it is charged with liquid nitrogen, which the absorbent soaks up completely; any excess is poured off. The result is a vapour-phase environment well below –150 °C with no free liquid that could spill.

This design has two advantages. Samples stay in the vapour phase and never touch liquid nitrogen, which lowers the risk of cross-contamination. And because the nitrogen is fully absorbed, these shippers are not regulated as dangerous goods for refrigerated liquefied gases under the IATA Dangerous Goods Regulations (Special Provision A152), so they can fly as air cargo.

Qualifying the dry shipper

Every container type used for investigational or commercial product needs qualification, covering:

  • Hold time under realistic conditions: measured with a typical payload, not just empty
  • Temperature profiles at the extremes: summer and winter profiles, extended transit times
  • Orientation tests: performance when tipped or shipped on its side
  • Charging procedure: an SOP that defines how long the shipper is charged and how readiness is verified

Hold time depends on model, payload and ambient conditions, and is matched to each route with a clear reserve over planned transit. Our dry shipper selection guide for cryogenic transport covers the selection criteria in detail.

Data loggers: the evidence behind every dose

Without a temperature record there is no proof that a dose stayed below –150 °C in transit. Modern data loggers sample the internal temperature at short intervals, store the readings in a tamper-evident way and allow a fast release decision on arrival. Some systems also report location and temperature in real time, so the team can still intervene when a shipment is delayed.

The logger itself must be calibrated, rated for temperatures below –150 °C, and its data unambiguously linked to the shipment and therefore to the dose.

Chain of identity and chain of custody

Two terms define the cell therapy supply chain:

  • Chain of identity (COI): the unique, continuous link between patient, starting material and finished product. One identifier follows every unit from apheresis to infusion, so no patient ever receives someone else's dose.
  • Chain of custody (COC): the complete record of who held the shipment, when, where and under what conditions. Every handover is logged with time, person and temperature status.

COI protects the patient from mix-ups; COC protects product quality. Both have to continue inside the hospital's cryogenic storage, because the chain does not end at the loading dock. It only changes container.

How is GDP compliance regulated in cryogenic transportation?

Shipping cell therapies sits under several frameworks at once:

  • EU GDP Guidelines (2013/C 343/01): require qualified transport containers, validated routes, temperature monitoring, risk management and clearly defined responsibilities between manufacturer and courier.
  • EU GMP Part IV for ATMPs: the GMP guidelines for advanced therapy medicinal products also cover storage and transport up to the point of supply, including traceability.
  • ISO 21973: sets out general requirements for transporting cells for therapeutic use, from planning and container selection to documentation.
  • IATA regulations: govern how dry shippers are classified for air freight and, depending on the material, how biological substances are packed.
  • FACT-JACIE Standards: define how collection and treatment centres receive, store and release cellular products.

In practice these requirements are translated into quality agreements between manufacturer, courier and hospital. On site, what matters is that receipt, interim storage and return of shippers are written into SOPs and that the equipment involved is qualified. For the trial setting, see our article on cell therapy clinical trial storage.

Shipping and storage as one system

The cold chain does not stop at the hospital door. The dose moves into a cryogenic tank, often stays there for days or weeks, and is retrieved on treatment day. Containers, racks, cassettes and monitoring should therefore fit together: a bag that travels in a cassette inside the dry shipper should move into the storage tank without repacking. Every extra handling step is a risk.

Consarctic® is a market-leading German manufacturer of cryogenic systems for the life sciences, serving customers in more than 30 countries, and covers this chain as one integrated system: BIOFREEZE® controlled rate freezers for freezing, ABV+, ABS+, BSD+ and BSF+ tanks for storage, and the ASR+ series for transport. The ASR+ cryogenic transport containers are dry shippers with no free liquid nitrogen, which makes them IATA-compliant for air transport, and are available with integrated data loggers for continuous temperature documentation. Several sizes cover everything from small clinical shipments to larger transfers between sites.

Consarctic has been certified to ISO 13485 since 2003 and supports customers with IQ/OQ by certified technicians and a 24/7 emergency service. For temperature validation of dry shippers, read our article on cryogenic sample shipping with the ASR+ series.

Checklist for cell and gene therapy shipping

  • Hold time of every dry shipper type qualified with a real payload
  • Charging procedure defined in an SOP and documented per shipment
  • Calibrated data logger in every shipment, data linked to the dose
  • Chain of identity unbroken from apheresis to infusion
  • Every handover logged with time, person and temperature status
  • Pre-cooled tools and a rehearsed sequence for transfers
  • Reserve time for customs and delays built into route planning
  • Receipt and interim storage at the clinic qualified

Frequently Asked Questions (FAQ)

How are CAR-T cells shipped?

After manufacturing, CAR-T cells are frozen at a controlled rate in cryobags and shipped in a dry shipper in the vapour phase of liquid nitrogen, below –150 °C, to the treatment centre. A data logger records the temperature, and a unique identifier keeps the dose linked to its patient. The apheresis starting material travels to the manufacturer either fresh at 2–8 °C or cryopreserved, depending on the process.

What is chain of identity in cell therapy?

Chain of identity is the unbroken link between a patient, their starting material and the finished product across every step of a personalised therapy. A unique identifier follows each unit from collection to infusion, so that no patient can receive another patient's dose.

How long does a dry shipper hold its temperature?

It depends on the model, payload, ambient temperature and orientation. Depending on size, hold times range from a few days to several weeks. For cell therapy shipments, hold time is qualified under realistic conditions and matched to planned transit with a clear reserve.

How is GDP compliance regulated within cryogenic transportation?

In the EU, the GDP Guidelines (2013/C 343/01) and the GMP guidelines for ATMPs apply, and air freight follows IATA regulations. ISO 21973 sets general requirements for transporting therapeutic cells, and collection and treatment centres additionally follow FACT-JACIE Standards. Compliance is documented through qualified containers, validated routes, continuous temperature records and quality agreements.

Safe logistics starts with the right container

In cell and gene therapy logistics, success is decided less by the distance than by the care taken at every handover. Qualified dry shippers, complete temperature data and an unbroken chain of identity turn a risky journey into a controlled process.

Planning cell therapy shipping routes or qualifying your dry shippers? Talk to Consarctic's cryogenics specialists about the ASR+ series and the right cryogenic infrastructure for your site.